CHAPTER 2 DEPENDENCE FUNCTIONS

Notes on STEP Command

Exceptional Step Execution

When executing the instructions listed in the notes on the GO command as invalid breakpoints and abnormal

breakpoints, such instructions and the next instruction are executed as a single instruction. Furthermore, if

such instructions are continuous, then all these continuous instructions and the next instruction are executed

as a single instruction.

Step Execution that won't Break

Note that no break occurs after step operation when both the following conditions are met at one time.

When step instruction longer than 2 bytes length and last code ends at even address

When breakpoint already set at last address (This "already-set" breakpoint is an invalid breakpoint that
won't break, because it has been set at an address other than the starting address of an instruction.)

Controlling Watchdog Timer

It is possible to select "No reset generated by watchdog timer counter overflow" while executing a program

using the GO, STEP, CALL commands.

Use the ENABLE WATCHDOG, DISABLE WATCHDOG commands to control the watchdog timer.

- ENABLE WATCHDOG

:

Reset generated by watchdog timer counter overflow

- DISABLE WATCHDOG

:

No reset generated by watchdog timer counter overflow

The start-up default in this program is "Reset generated by watchdog timer counter overflow".

[Example]

>DISABLE WATCHDOG

>GO