73

CHAPTER 2 DEPENDENCE FUNCTIONS

2.2.1.5

Timer Minimum Measurement Unit

The timer minimum measurement unit affects the sequencer, the emulation timer and the
performance measurement timer.

Setting Timer Minimum Measurement Unit

Choose either 1

μs or 100 ns as the timer minimum measurement unit for the emulator for measuring time.

The minimum measurement unit for the following timers is changed depending on this setup.

Timer values of sequencer (timer conditions at each level)

Emulation timer

Performance measurement timer

Table 2.2-3 shows the maximum measurement time length of each timer when 1

μs or 100 ns is selected as

the minimum measurement unit.

When the minimum measurement unit is changed, the measurement values of each timer are cleared as well.

The default setting is 1

μs.

Use the following commands to control timers.

SET TIMERSCALE :

Sets minimum measurement unit for timers

SHOW TIMERSCALE :

Displays status of minimum measurement unit setting for timers

[Example]

>SET TIMERSCALE/100N

>SHOW TIMERSCALE

Timer scale : 100ns

>

Table 2.2-3 Maximum Measurement Time Length of Each Timer

1

μ

s selected

100 ns selected

Sequencer timer

About 16 seconds

About 1.6 seconds

Emulation timer

About 70 minutes

About 7 minutes

Performance measurement timer

About 70 minutes

About 7 minutes