background image

73

CHAPTER 2 DEPENDENCE FUNCTIONS

2.2.1.5

Timer Minimum Measurement Unit

The timer minimum measurement unit affects the sequencer, the emulation timer and the
performance measurement timer.

■

Setting Timer Minimum Measurement Unit

Choose either 1

μs or 100 ns as the timer minimum measurement unit for the emulator for measuring time.

The minimum measurement unit for the following timers is changed depending on this setup.

•

Timer values of sequencer (timer conditions at each level)

•

Emulation timer

•

Performance measurement timer

Table 2.2-3 shows the maximum measurement time length of each timer when 1

μs or 100 ns is selected as

the minimum measurement unit.

When the minimum measurement unit is changed, the measurement values of each timer are cleared as well.

The default setting is 1

μs.

Use the following commands to control timers.

SET TIMERSCALE :

Sets minimum measurement unit for timers

SHOW TIMERSCALE :

Displays status of minimum measurement unit setting for timers

[Example]

>SET TIMERSCALE/100N

>SHOW TIMERSCALE

Timer scale : 100ns

>

Table 2.2-3 Maximum Measurement Time Length of Each Timer

1

μ

s selected

100 ns selected

Sequencer timer

About 16 seconds

About 1.6 seconds

Emulation timer

About 70 minutes

About 7 minutes

Performance measurement timer

About 70 minutes

About 7 minutes

Advertising