Figure 138. transmit data by polling – Intel 386 User Manual

Page 408

Advertising
background image

13-9

SYNCHRONOUS SERIAL I/O UNIT

Figure 13-8. Transmit Data by Polling

A3394-01

No

TUE=1

?

Yes

Error

Routine

AUTOTXM=1

?

No

Yes

AUTOTXM=1

?

Enable Transmitter

TEN=1

THBE=1

?

Yes

Delay To Allow Transmitter

To Shift First Bit Out

Disable Transmitter

TEN=0

No

No

Yes

Write Data to Buffer

(SSIOTBUF)

Initialize SSIO

Write Data to Buffer

(SSIOTBUF)