Figure 175. power control register (pwrcon) – Intel 386 User Manual

Page 506

Advertising
background image

17-11

WATCHDOG TIMER UNIT

Figure 17-5. Power Control Register (PWRCON)

Power Control Register
PWRCON
(read/write)

Expanded Addr:
ISA Addr:
Reset State:

F800H

00H

7

0

WDTRDY

HSREADY

PC1

PC0

Bit

Number

Bit

Mnemonic

Function

7–4

Reserved. These bits are undefined; for compatibility with future devices,
do not modify these bits.

3

WDTRDY

Watch Dog Timer Ready:

0 = An external READY must be generated to terminate the cycle when

the WDT times out in Bus Monitor Mode.

1 = Internal logic generates READY# to terminate the cycle when the

WDT times out in Bus Monitor Mode.

2

HSREADY

Halt/Shutdown Ready:

0 = An external ready must be generated to terminate a HALT/Shutdown

cycle.

1 = Internal logic generates READY# to terminate a HALT/Shutdown

cycle.

1–0

PC1:0

Power Control:

Program these bits, then execute a HALT instruction. The device enters
the programmed mode when READY# (internal or external) terminates
the halt bus cycle. When these bits have equal values, the HALT
instruction causes a normal halt and the device remains in active mode.

PC1

PC0

0

0

active mode

1

0

idle mode

0

1

powerdown mode

1

1

active mode

Advertising