D.58 ssiobaud – Intel 386 User Manual

Page 623

Advertising
background image

Intel386™ EX EMBEDDED MICROPROCESSOR USER’S MANUAL

D-58

D.58 SSIOBAUD

SSIO Baud-rate Control
SSIOBAUD
(read/write)

Expanded Addr:
ISA Addr:
Reset State:

F484H

00H

7

0

BEN

BV6

BV5

BV4

BV3

BV2

BV1

BV0

Bit

Number

Bit

Mnemonic

Function

7

BEN

Baud-rate Generator Enable:

Setting this bit enables the baud-rate generator. Clearing this bit disables
the baud-rate generator, clears the baud-rate count value, and forces the
baud rate clock to zero.

6–0

BV6:0

Baud-rate Value:

The baud-rate value (BV) is the reload value for the baud-rate
generator’s seven-bit down counter. The baud-rate generator’s output is
a function of BV and the baud-rate generator’s input (BCLKIN), as
follows.

(Hz)

If you know the desired output baud-rate frequency, you can determine
BV as follows.

baud-rate output frequency (Hz)

BCLKIN

2BV

2

+

----------------------

=

BV

BCLKIN

2

baud-rate output frequency

Ч

---------------------------------------------------------------------------------

1

=