2 default alarm severity, 3 alarm severity criterion – Siemens S223 User Manual

Page 113

Advertising
background image

User Manual UMN:CLI
SURPASS hiD 6615 S223/S323 R1.5

A50010-Y3-C150-2-7619 113

7.1.9.2 Default

Alarm

Severity

To configure a priority of alarm, use the following command.

Command Mode

Description

snmp alarm-severity default

{critical | major | minor | warning
| intermediate}

Global

Configures the priority of alarm.
(default: minor)

7.1.9.3 Alarm

Severity

Criterion

You can set an alarm severity criterion to make an alarm be shown only in case of se-
lected severity or higher. For example, if an alarm severity criterion has been set to major,
you will see only an alarm whose severity is major or critical.

To configure alarm-severity criteria in CLI, use the following command.

Command Mode

Description

snmp alarm-severity criteria

{critical | major | minor | warning
| intermediate}

Global

Configures the severity criterion.
(default: warning)

The order of alarm severity is critical > major > minor > warning > intermediate.

The alarm severity option is valid only in ACI-E.

i

!

Advertising
This manual is related to the following products: