5 activating rmon history, 6 deleting configuration of rmon history, 7 displaying rmon history – Siemens S223 User Manual

Page 128

Advertising
background image

UMN:CLI User Manual

SURPASS hiD 6615 S223/S323 R1.5

128 A50010-Y3-C150-2-7619

1 sec is the minimum time which can be selected. But the minimum sampling interval
currently is 30 sec, i.e., all intervals will be round up to a multiple of 30 seconds.

7.4.1.5

Activating RMON History

To activate RMON history, use the following command.

Command Mode

Description

active

RMON

Activates RMON history.

Before activating RMON history, check if your configuration is correct. After RMON history
is activated, you cannot change its configuration. If you need to change configuration, you
need to delete the RMON history and configure it again.

7.4.1.6

Deleting Configuration of RMON History

When you need to change a configuration of RMON history, you should delete an existing
RMON history.

To delete RMON history, use the following command.

Command Mode

Description

no rmon-history

<1-65535>

RMON

Deletes RMON history of specified number, enter the
value for deleting.

7.4.1.7 Displaying

RMON

History

To display RMON history, use the following command.

Command Mode

Description

show

running-config

rmon-

history

All

Shows a configured RMON history.

Always the last values will be displayed but no more than the number of the granted
buckets.

The following is an example of displaying RMON history.

SWITCH(config-rmonhistory [5])# show running-config rmon-history

!

rmon-history 5

owner test

data-source ifindex.hdlc1

interval 60

requested-buckets 25

active

!

SWITCH(config-rmonhistory [5])#

i

i

i

Advertising
This manual is related to the following products: