2 auto system rebooting, 2 system authentication, 2 auto system rebooting 4.2 – Siemens S223 User Manual

Page 49: System authentication

Advertising
background image

User Manual UMN:CLI
SURPASS hiD 6615 S223/S323 R1.5

A50010-Y3-C150-2-7619 49

4.1.8.2

Auto System Rebooting

The hiD 6615 S223/S323 reboots the system according to user’s configuration. There are
two basises for system rebooting. These are CPU and memory. CPU is rebooted in case
CPU Load or Interrupt Load continues for the configured time. Memory is automatically
rebooted in case memory low occurs as the configured times.

To enable auto system rebooting function, use the following command.

Command Mode

Description

auto-reset cpu

<50-100> <1-100>

TIME

Configure to reboot the system automatically in case
an average of CPU or interrupt load exceeds the con-
figured value during the user-defined time.
50-100: average of CPU load per 1 minute
1-100: average of interrupt load
TIME: minute

auto-reset memory

<1-120> <1-

10>

Configure to reboot the system automatically in case
memory low occurs as the configured value.
1-120: time of memory low
1-10: count of memory low(The default is 5)

no auto-reset

{cpu | memory}

Bridge

Disables auto system rebooting.

To show auto system rebooting configuration, use the following command.

Command Mode

Description

show auto-reset

{cpu | memory}

Global/

Bridge

Shows a configuration of auto-rebooting function.

The following is an example of configuring auto-restarting function in case CPU load or
Interrupt load maintains over 70% during 60 seconds and viewing the configuration.

SWITCH(config)# SWITCH(bridge)# auto-reset cpu 70 70 1

SWITCH(bridge)# show auto-reset cpu

------------------------------

Auto-Reset Configuration(CPU)

------------------------------

auto-reset: on

cpu load: 70

interrupt load: 70

continuation time: 1

SWITCH(bridge)#

4.2 System

Authentication

For the enhanced system security, the hiD 6615 S223/S323 provides two authentication
methods to access the switch using Remote Authentication Dial-In User Service (RA-
DIUS) and Terminal Access Controller Access Control System Plus (TACACS+).