8.6 Flood

Guard

Flood-guard limits number of packets, how many packets can be transmitted, in config-
ured bandwidth, whereas Rate limit controls packets through configuring width of band-
width, which packets pass through. This function prevents receiving packets more than
configured amount without enlarging bandwidth.

<Rate Limit>

<Flood Guard>

Bandwidth

Control

bandwidth

Configure Rate Limit on port

1

2

3

n

:

:

n+1

n+2

Configure Flood-guard to

allow packets as many as ‘n’

per a second

n’ packets

allowed for

a second

Packets

over thrown

away

Fig. 8.30

Rate Limit and Flood Guard

8.6.1 Configuring

Flood-Guard

To configure the number of packets, which can be transmitted in a second, use the follow-
ing command.

Command Mode

Description

mac-flood-guard

PORTS <1-

2000000>

Limits the number of packets which can be transmitted
to the port for 1 second.

no mac-flood-guard PORTS

Bridge

Clears the configured Flood Guard.

To display a configuration of flood guard, use the following command.

Command Mode

Description

show mac-flood-guard

[macs]

Bridge

Shows the configured Flood Guard.