8 displaying bpdu configuration – Siemens S223 User Manual

Page 224

Advertising
background image

UMN:CLI User Manual

SURPASS hiD 6615 S223/S323 R1.5

224 A50010-Y3-C150-2-7619

To enable/disable self loop detection, use the following command.

Command Mode

Description

self-loop-detect

{enable | dis-

able

}

Bridge Enables/disables

self loop detection function.

To display a configuration for BPDU, use the following command.

Command Mode

Description

show self-loop-detect

Shows status of self loop detection and a port where
loop is happed.

show self-loop-detect

{all |

PORTS

}

Enable

Global
Bridge

Shows self loop detection status on specified ports:
all: all the ports
PORTS: selected port

8.3.9.8

Displaying BPDU Configuration

To display the configuration for BPDU, use the following command.

Command Mode

Description

show stp mst

MSTID-RANGE {all

| PORTS} [detail]

show stp mst

MSTID-RANGE all

[detail]

show stp mst

MSTID-RANGE

PORTS

[detail]

Shows a configuration for BPDU for STP, RSTP and
MSTP.

show stp pvst VLAN-RANGE

[all | PORTS] [detail]

Enable

Global
Bridge

Shows a configuration for BPDU for PVSTP and
PVRSTP.

Advertising
This manual is related to the following products: