1 source port of statistical data, 2 subject of rmon history, 3 number of sample data – Siemens S223 User Manual

Page 127: 4 interval of sample inquiry

Advertising
background image

User Manual UMN:CLI
SURPASS hiD 6615 S223/S323 R1.5

A50010-Y3-C150-2-7619 127

want to list available commands.

The following is an example of listing available commands on RMON Configuration mode.

SWITCH(config-rmonhistory[5])# ?

RMON history configuration commands:

active

Activate the history

data-source

Set data source port

do

To run exec commands in config mode

exit

End current mode and down to previous mode

help

Description of the interactive help system

interval

Define the time interval for the history

owner

Assign the owner who define and is using the history

resources

requested-buckets

Define the bucket count for the interval

show

Show running system information

SWITCH(config-rmonhistory[5])#

7.4.1.1

Source Port of Statistical Data

To specify a source port of statistical data, use the following command.

Command Mode

Description

data-source

NAME RMON

Specifies a data object ID.
NAME: enters a data object ID. (ex. ifindex.n1/port1)

7.4.1.2

Subject of RMON History

To identify subject using RMON history, use the following command.

Command Mode

Description

owner

NAME RMON

Identifies subject using related data, enter the name
(max. 32 characters).

7.4.1.3

Number of Sample Data

To configure the number of sample data of RMON history, use the following command.

Command Mode

Description

requested-buckets

<1-65535>

RMON

Defines a bucket count for the interval, enter the num-
ber of buckets.
1-65535: bucket number (default: 50)

7.4.1.4

Interval of Sample Inquiry

To configure the interval of sample inquiry in terms of second, use the following command.

Command Mode

Description

interval

<1-3600>

RMON

Defines the time interval for the history (in seconds),
enter the value. (default: 1800)

Advertising
This manual is related to the following products: