To disable password encryption, use the following command.

Command Mode

Description

no service password-encryption

Global

Disables password encryption.

4.1.3 Changing

Login

Password

To configure a password for created account, use the following command.

Command Mode

Description

passwd

[NAME]

Global

Configures a password for created account.

The following is an example of changing password.

SWITCH(config)# passwd Siemens

Changing password for Siemens

Enter the new password (minimum of 5, maximum of 8 characters)

Please use a combination of upper and lower case letters and numbers.

Enter new password:junior95

Re-enter new password:junior95

Password changed.

SWITCH(config)#

The password you are entering won’t be seen in the screen, so please be careful not to
make mistake.

4.1.4

Management for System Account

4.1.4.1 Creating

System

Account

For the hiD 6615 S223/S323, the administrator can create a system account. In addition,
it is possible to set the security level from 0 to 15 to enhance the system security.

To create a system account, use the following command.

Command Mode

Description

user add NAME DESCRIPTION

Creates a system account.

user add NAME level

<0-15>

DESCRIPTION

Global

Creates a system account with a security level.

The account of level 0 to level 14 without any configuring authority only can use exit and
help

in Privileged EXEC View mode and cannot access to Privileged EXEC Enable mode.

The account with the highest level 15 has a read-write authority.

i

!