14 assigning ip address of ftp client, 2 configuration management, 1 displaying system configuration – Siemens S223 User Manual

Page 91: Assigning ip address of ftp client, Configuration management, Displaying system configuration

Advertising
background image

User Manual UMN:CLI
SURPASS hiD 6615 S223/S323 R1.5

A50010-Y3-C150-2-7619 91

6.1.14

Assigning IP Address of FTP Client

Serveral IP addresses can be assigned on hiD 6615 S223/S323. But user can specify
one source IP address connecting FTP server when the switch is a client. To configure
FTP binding address as a source IP address when hiD 6615 S223/S323 as a client con-
nects to FTP server, use the following command.

Command Mode

Description

ftp bind-address A.B.C.D

Binds a source IP address for connecting to FTP
server..

no ftp bind-address

Global

Deletes FTP bind-address

Please be careful that the FTP bind-address is also applied to TFTP server’s bind-
address.

6.2 Configuration

Management

You can verify if the system configurations are correct and save them in the system. This
section contains the following functions.

Displaying System Configuration

Saving System Configuration

Auto-Saving

System Configuration File

Restoring Default Configuration

6.2.1

Displaying System Configuration

To display a current running configuration of the system, use the following command.

Command Mode

Description

show running-config

Shows a configuration of the system.

show running-config

{admin-

rule

| arp | bridge | dns | full |

hostname

| instance | interface

INTERFACE

I login | pm | qos |

rmon-alarm

| rmon-event | rmon-

history

| router {bgp | pim | rip |

ospf

| vrrp} | rule | snmp | syslog

| time-out | time-zone | time-out}

Shows a configuration of the system with the specific
option.

show running-config router

{bgp | ospf | pim | rip | vrrp}

All

Shows only the configuration that corresponds to each
option.