5 Port

Configuration

It is possible for user to configure basic environment such as auto-negotiate, transmit rate,
and flow control of the hiD 6615 S223/S323 port. Also, it includes instructions how to con-
figure port mirroring and port as basic.

5.1 Port

Basic

It is possible to configure default environment of port such as port state, speed. To con-
figure port, you need to open Bridge Configuration mode by using the command, bridge,
on Global Configuration mode. When you begin Bridge Configuration mode, system
prompt will be changed from SWITCH(config)# to SWITCH(bridge)#.

SWITCH(config)# bridge

SWITCH(bridge)#

The hiD 6615 S223/S323 have 12 electrical and optical combo 100/1000Base-X Ethernet
ports. The direction to configure each port is different depending on its features. Read the
below instruction carefully and follow it before you configure.

Refer to below figure for front interfaces of hiD 6615 S223/S323.

RUN

RPU

DIAG

RX

LNK

ACT

MGMT

CONSOLE

TX

1

1

2

3

4

5

6

7

8

9

10

11

12

L/A

S323

1 G

2 3 4 5 6 7 8 9 10 11 12

SURPASS

hiD 6615

Fig. 5.1

hiD 6615 S223/S323 Interface

To display the configuration of the physical port, use the following command.

Command Mode

Description

show port

[PORTS]

Enable

Global
Bridge

Shows port configuration.

When you use the command, show port command, if you input letter at port-number, the
message, “% Invalid port: port'” will be displayed, and if you input wrong number, the
message, “% Invalid range: 100 [1-18]” will be displayed.

SWITCH(bridge)# show port port

%Invalid port: port

SWITCH(bridge)# show port 100

%Invalid range: 100 [1-18]

SWITCH(bridge)#