5 authentication password, Fig. 8.29, Vrrp track – Siemens S223 User Manual

Page 232: Internet

Advertising
background image

UMN:CLI User Manual

SURPASS hiD 6615 S223/S323 R1.5

232 A50010-Y3-C150-2-7619

Internet

Master Router 1

IP : 10.0.0.3/24

Default Gateway

: 10.0.0.5/24

Backup Router 1

IP : 10.0.0.2/24

Backup Router 2

IP : 10.0.0.1/24

Virtual Router
Associate IP : 10.0.0.5/24

1. Link Down

If the interface doesn’t recognize to
be Link down, it is supposed to be
inaccessible to Master Router.
Therefore the users on the interface
are not able to communicate.

2.

Counter

measure

If “Link down” happens, by giving low
priority automatically to Master Router,
Master Router will be changed at the
same time with Link down.

3.

Fig. 8.29

VRRP Track

To configure VRRP Track, use the following command.

Command Mode

Description

track interface INTERFACE

pri-

ority

<1-254>

VRRP

Configures VRRP Track. The Priority becomes lower
as the configured value.

To release VRRP Track configuration, use the following command.

Command Mode

Description

no track interface INTERFACE

VRRP

Disables VRRP Track configuration.

8.4.1.5 Authentication

Password

If anyone knows Group ID and Associated IP address, he can configure another device
as a Virtual Router. To prevent this, user needs to configure a password, named authenti-
cation password that can be used only in Virtual Router user configured.

Advertising