2 loss of test packet (lotp), 3 configuring erp, 1 erp domain – Siemens S223 User Manual

Page 267: Loss of test packet (lotp), Configuring erp, Fig. 8.38, Ring recovery

Advertising
background image

User Manual UMN:CLI
SURPASS hiD 6615 S223/S323 R1.5

A50010-Y3-C150-2-7619 267

3. Unblock the
port recovered
from Link Failure

2. Send RM Link Up message

Normal Node

Normal Node

Normal Node

RM Node

P

S

2. Send RM Link

Up message

1. Block RM Node of

secondary port

Fig. 8.38

Ring Recovery

8.9.2

Loss of Test Packet (LOTP)

ERP recognizes the Link Failure using Loss of Test Packet (LOTP). RM Node regularly
sends RM Test Packet message. If the message is not retransmitted to RM Node through
Ethernet Ring, it means that Loop doesn’t occur. Therefore, RM Node unblocks Secon-
dary port. The condition that RM Test Packet from RM Node doesn’t return is LOTP state.

On the other hand, if RM Test Packet is retransmitted to RM Note through Ethernet Ring,
Loop may occur. In this condition, RM Node blocks Secondary port.

8.9.3 Configuring

ERP

8.9.3.1 ERP

Domain

To realize ERP, you should fist configure domain for ERP. To configure the domain, use
the following command.

Command Mode

Description

erp domain

DOMAIN-ID

Creates ERP domain.
DOMAIN-ID: control VLAN ID of domain <1-4094>

no erp domain

{all | DOMAIN-ID}

Bridge

Deletes ERP domain.

To specify a description for configured domain, use the following command.

Command Mode

Description

erp description DOMAIN-ID

DESCRIPTION

Bridge

Specifies a description of domain.