Fig. 8.36, Ring protection, Fig. 8.37 – Siemens S223 User Manual

Page 266: Link failure recovery

Advertising
background image

UMN:CLI User Manual

SURPASS hiD 6615 S223/S323 R1.5

266 A50010-Y3-C150-2-7619

Normal Node

Normal Node

Normal Node

RM Node

P

S

1. Secondary port of RM node is

changed as unblocking state

2. Send Link

Down Message

2. Send Link

Down Message

Fig. 8.36

Ring Protection

When a Link Failure is recovered, a temporary loop may occur. To rectify this condition,
ERP sends a “link up” message to the RM. The RM will logically block the protected
VLANs on its secondary port and generate a “RM link up” packet to make sure that all
transit nodes are properly reconfigured. This completes fault restoration and the ring is
back in normal state.

2. Nodes detecting Link Failure

send Link Down message

2. Nodes detecting Link Failure

send Link Down message

Normal Node

Normal Node

1. Link Failure recover
blocks the port
recovered from Link
Failure

Normal Node

RM Node

P

S

Fig. 8.37

Link Failure Recovery