Commissioning

Display

START BUTTON

RUN

In Local Mode (P100 = 0, 4, 6), this button will start the drive.

STOP BUTTON

STOP

Stops the drive, regardless of which mode the drive is in.

WARNING!

When JOG is active, the STOP button will not stop the

drive!

ROTATION
In Local Mode (P100 = 0, 4, 6), this selects the motor rotation direction:

- The LED for the present rotation direction (FWD or REV) will be on

- Press R/F; the LED for the opposite rotation direction will blink

- Press M within 4 seconds to confirm the change

- The blinking direction LED will turn on, and the other LED will turn off

When rotation direction is changed while the drive is running, the commanded direction LED will blink

until the drive is controlling the motor in the selected direction.
MODE

Used to enter/exit the Parameter Menu when programming the drive and to enter a changed parameter

value.

UP AND DOWN BUTTONS

Used for programming and can also be used as a reference for speed, PID setpoint, or torque setpoint.
When the s and t buttons are the active reference, the middle LED on the left side of the display will

be on.

Display

INDICATING LEDs (on 4-character display)

FWD

FWD LED: Indicate the present rotation direction is forward. Refer to ROTATION description above.

REV

REV LED: Indicate the present rotation direction is reverse. Refer to ROTATION description above.

AUTO

AUTO LED: Indicates that the drive has been put into Auto mode from one of the TB13 inputs (P121…

P124 set to 1…7). Also indicates that PID mode is active (if enabled).

RUN

RUN LED: Indicates that the drive is running.

L M

s t

LED: Indicates that the s t are the active reference.