Technical data, 2 ratings, 240vac models – LEESON SM4 Series Flux Vector User Manual

Page 7

Advertising
background image

6

Technical data

2.2

Ratings

120VAC Doubler / 240VAC Models

Type

Power

[Hp/kW]

Mains

Output Current

SM2

Watts

Loss

SM4

Watt

Loss

Voltage

(1)

I

in

(120V)

I

in

(240V)

I

n

CLim

max

(2)

174603

0.33 / 0.25

120 V Single-phase (1/N/PE)

(90 … 132 V)

OR

240 V Single-phase (2/PE)

(170 … 264 V)

6.8

3.4

1.7

200

24

174604-

174652

0.5 / 0.37

9.2

4.6

2.4

200

32

32

174605-

174653

1 / 0.75

16.6

8.3

4.2

200

52

41

174651-

174654

1.5 / 1.1

20.0

10.0

6.0

200

74

74

240VAC Models

Type

Power

[Hp/kW]

Mains

Output Current

SM2

Watts

Loss

SM4

Watts

Loss

Voltage

(1)

I

in

1~ (2/PE)

I

in

3~ (3/PE)

I

n

CLim

max

(2)

174606

0.33 / 0.25

240 V Single Phase (2/PE)

3.4

-

1.7

200

20

174607-174655

0.5 / 0.37

240 V Single-phase (2/PE)

OR

240 V Three-phase (3/PE)

(170 … 264 V)

5.1

2.9

2.4

200

27

30

174608-174656

1 / 0.75

8.8

5.0

4.2

200

41

42

174609-174657

1.5 / 1.1

12.0

6.9

6.0

200

64

63

174610-174658

2 / 1.5

13.3

8.1

7.0

200

75

73

174611-174659

3 / 2.2

17.1

10.8

9.6

200

103

97

174612

1.5 / 1.1

240 V Three-phase (3/PE)

(170 V … 264 V)

-

6.9

6.0

200

64

59

174613

2 / 1.5

-

8.1

7.0

200

75

69

174614

3 / 2.2

-

10.8

9.6

200

103

93

174615-174660

5 / 4.0

-

18.6

16.5

200

154

139

174616-174661

7.5 / 5.5

-

26

23

200

225

167

174617-174662

10 / 7.5

-

33

29

200

274

242

174618

15 / 11

-

48

42

180

485

468

174619

20 / 15

-

59

54

180

614

591

(1) Frequency Range: 48 Hz … 62 Hz

(2) Current Limit (CLim) is a percentage of the output current, I

n

. CLim

max

is the maximum setting for P171.

Advertising