Appendix a, Appendix, A.1 permissable cable lengths – LEESON SM4 Series Flux Vector User Manual

Page 68

Advertising
background image

Appendix A

A.1

Permissable Cable Lengths

The table herein lists the permissable cable lengths for use with an SM Flux Vector inverter with an

internal EMC filter.

NOTE

This table is intended as a reference guideline only; application results may

vary. The values in this table are based on testing with commonly available

low-capacitance shielded cable and commonly available AC induction motors.

Testing is conducted at worst case speeds and loads.

Maximum Permissible Cable Lengths (Meters) for SM Flux Vector Models

with Internal EMC Filters

Mains

Model

4 kHz Carrier

(P166 = 0)

6 kHz Carrier

(P166 = 1)

8 kHz Carrier

(P166 = 2)

10 kHz Carrier

(P166 = 3)

Class

A

Class

B

Class

A

Class

B

Class

A

Class

B

Class

A

Class

B

240 V

, 1-phase (2/PE)

ESV251GG2SFG 38

12

35

10

33

5

30

N/A

ESV371GG2SFG 38

12

35

10

33

5

30

N/A

ESV751GG2SFG 38

12

35

10

33

5

30

N/A

ESV112GG2SFG 38

12

35

10

33

5

30

N/A

ESV152GG2SFG 38

12

35

10

33

5

30

N/A

ESV222GG2SFG 38

12

35

10

33

5

30

N/A

400/480 V

,3-phase

(3/PE)

ESV371GG4TFG 30

4

25

2

20

N/A

10

N/A

ESV751GG4TFG 30

4

25

2

20

N/A

10

N/A

ESV112GG4TFG 30

4

25

2

20

N/A

10

N/A

ESV152GG4TFG 30

4

25

2

20

N/A

10

N/A

ESV222GG4TFG 30

4

25

2

20

N/A

10

N/A

ESV302GG4TFG 30

4

25

2

20

N/A

10

N/A

ESV402GG4TFG 54

5

48

3

42

2

N/A

N/A

ESV552GG4TFG 54

5

48

3

42

2

N/A

N/A

ESV752GG4TFG 54

5

48

3

42

2

N/A

N/A

NOTE: The “