Commissioning, 1 sequencer parameters, Sequencer flow diagram – LEESON SM4 Series Flux Vector User Manual

Page 59

Advertising
background image

58

Commissioning

4.5.9.1 Sequencer Parameters

WARNING

If the input defined to “Start Sequence” is opened during a sequence, the

drive will exit sequencer mode and will run at the specified standard or

alternate speed source (dependent on drive configuration).

Drive Stop/Start Control

TB-13

C

TB-13

B

TB-13

A

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

P701

P702

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

P703

P121

24

P122

24

P123

24

3

2

3

P700

0

2

Sequencer

mode

disabled

1

Start

Segment

Start

Segment

Start

Segment

“Start Segment” number selection

WARNING

If none of the digital inputs (TB-13A,B,C or D) are asserted

but a start signal is given from the Start/Stop source (P100)

then the drive will run at the output frequency value governed by

the frequency reference source (P101).

Start from

Local Keypad

Start from

Terminal Strip

0

1

2

(2)

P100

Start from

Remote Keypad

3

(1)

Start from Network

(SMV communications

module)

Notes

(1)

Refer to relevant communications module user guide for starting from a

communications network, RS485 etc..

(2)

Refer to P100 description in the SMV Operating instructions for further

combinations of start sources.

> Selections shown as default values

Digital Input priority:

TB-13A - Lowest

TB-13B

TB-13C

Sequencer Flow Diagram

TB-13

D

24

P124

P704

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Segment

Start

TB-13D - Highest

(3)

TB-13D available on SMV models rated 15HP (11kW) or greater.

(3)

Notes

(1) Refer to relevant communications module user guide for

starting from a communications network, RS485 etc.

(2) Refer to P100 description in the Operating instructions for

further combinations of start sources.

(3) TB-13D available on models rated 15HP (11kW) or greater.

> Selections shown as default values

Advertising