Commissioning

Code

Possible Settings

IMPORTANT

No.

Name

Default Selection

WARNING!

If the input defined to “Start Sequence” is opened during a sequence, the drive will exit

sequencer mode and will run at the specified standard or alternate speed source (dependent on

drive configuration).
Note

• When input is activated, settings 1...7 override P101

• When TB-13A...TB-13C are configured for Auto References other than MOP, TB-13C overrides

TB-13B, and TB-13B overrides TB-13A. Any other Auto Reference will have priority over MOP.

• Settings 10...14 are only valid in Terminal Strip mode (P100 = 1, 4, 5)

• If Start/Run/Jog Forward and Start/Run/Jog Reverse are both activated, drive will STOP

• If Jog input is activated while the drive is running, the drive will enter Jog mode; when Jog

input is deactivated, drive will STOP

An F.AL fault will occur if the Assertion Level switch (ALsw) position does not match the

P120 setting and any of the digital inputs (P121...P123) are set to a value other than 0.

• An

F.IL

fault will occur under the following conditions:

- TB-13A...TB-13C settings are duplicated (each setting, except 0 and 3, can only be used

once)

- One input is set to “MOP Up” and another is not set to “MOP Down”, or vice-versa.

- One input is set to 10 and another input is set to 11…14.

- One input is set to 11 or 12 and another input is set for 13 or 14.

• Typical control circuits are shown below:

- If any input is set to 10, 12 or 14, P112 must be set to 1 for Reverse action to function.

Run / Stop

with Direction

P121 = 10

Start Forward /

Start Reverse

P121 = 11, P122 = 12

Run Forward /

Run Reverse

P121 = 13, P122 = 14

1

4

13A

FWD

REV

STOP

RUN

1

4

13A 13B

RUN

REV

RUN

FWD

FWD

REV

STOP

1

4 13A 13B

P125

Acceleration

Time 2

20.0 0.0 {s} 3600

• Selected using TB-13A...TB-13C

(P121...P123 = 17)

• For S-ramp accel/decel, adjust

P106

P126

Deceleration

Time 2

20.0 0.0 {s} 3600

P127

Deceleration

Time for

Auxiliary Ramp

to Stop

20.0 0.0 {s} 3600

• Selected using TB-13A...TB-13C

(P121...P123 = 19).

• For S-ramp accel/decel, adjust

P106

• Once executed, this ramp time has

priority over P105 and P126.

P129

Automatic

Accel/Decel rate

switch threshold

0.0

0.0 {Hz} 1000

If Actual Frequency < P129 Use

Accel/decel time #2 (P126/P127)

If Actual Frequency ≥ P129 Use

Accel/decel time #1 (P104/P105)