Commissioning – LEESON SM4 Series Flux Vector User Manual

Page 53

Advertising
background image

52

Commissioning

Code

Possible Settings

IMPORTANT

No.

Name

Default Selection

Segment #5

P730

Segment #5

Frequency

Setpoint

0.0

-500.0

{Hz}

500.0

If P112 = 1, negative sign forces

reverse direction

P731

Segment #5

Accel/Decel Time

20.0

0.0

{sec} 3600.0

P732

Segment #5

Time in current

step

0.0

0

0.0

{P708}

6553.5

0

{P708}

65535

Scaling/units depend on P708

Skip segment if time = 0

P733

Segment #5

Digital Output

State

0

Bit0 Relay

bit = 0: OFF (De-energized)

bit = 1: ON (Energized)

The corresponding digital output/

relay must be set to accept value the

from the sequencer: P140, P142=27

Bit1 TB14

P734

Segment #5

TB30

Analog Output

Value

0.00

0.00

{VDC} 10.00

TB30 configuration parameter must

be set to accept this value: P150

= 10

Segment #6

P735

Segment #6

Frequency

Setpoint

0.0

-500.0

{Hz}

500.0

If P112 = 1, negative sign forces

reverse direction

P736

Segment #6

Accel/Decel Time

20.0

0.0

{sec} 3600.0

P737

Segment #6

Time in current

step

0.0

0

0.0

{P708}

6553.5

0

{P708}

65535

Scaling/units depend on P708

Skip segment if time = 0

P738

Segment #6

Digital Output

State

0

Bit0 Relay

bit = 0: OFF (De-energized)

bit = 1: ON (Energized)

The corresponding digital output/

relay must be set to accept value the

from the sequencer: P140, P142=27

Bit1 TB14

P739

Segment #6

TB30

Analog Output

Value

0.00

0.00

{VDC} 10.00

TB30 configuration parameter must

be set to accept this value: P150

= 10

Segment #7

P740

Segment #7

Frequency

Setpoint

0.0

-500.0

{Hz}

500.0

If P112 = 1, negative sign forces

reverse direction

P741

Segment #7

Accel/Decel Time

20.0

0.0

{sec} 3600.0

P742

Segment #7

Time in current

step

0.0

0

0.0

{P708}

6553.5

0

{P708}

65535

Scaling/units depend on P708

Skip segment if time = 0