Commissioning

Code

Display Range

(READ ONLY)

IMPORTANT

No.

Name

P562

Sequencer: Time

Remaining in

Active Segment

0.0 {P708} 6553.5

0 {P708} 65535

Unit depends on P708 (0.1sec, sec or minutes)

P563

Sequencer:

Number of

cycles since

start

0 65535

P564

Sequencer:

Number of

cycles remaining

0 65535

Note: Parameters P560-P564 are visible only when P700 > 0 (i.e. the

sequencer is enabled)

4.5.7.1 Terminal and Protection Status Display

Parameter P530 allows monitoring of the control terminal

points and common drive conditions:

An illuminated LED segment indicates:

• the protective circuit is active (LED 1)

• the Logic Assertion Switch is set to High (+)

• input terminal is asserted (LED 2)

• output terminal is energized (LED 4)

• the Charge Relay is not a terminal, this segment will

be illuminated when the Charge Relay is energized

(LED 4)

4.5.7.2 Keypad Status Display

Parameter P531 allows monitoring of the keypad

pushbuttons:

An illuminated LED segment indicates when the button

is depressed.

LED 1 and LED 2 are used to indicate pushbutton

presses on a remote keypad that is attached to the

drive. LED 3 and LED 4 indicate button presses on the

local drive keypad.