Commissioning

Code

Possible Settings

IMPORTANT

No.

Name

Default Selection

P140

(cont)

Relay Output

TB-16, 17

0

11 Local Keypad Control Active

Energizes when the selected source

is active for start control

12 Terminal Strip Control Active
13 Remote Keypad Control Active
14 Network Control Active
15 Standard Reference Active

Energizes when P101 reference is

active

16 Auto Reference Active

Energizes when Auto Reference is

activated using TB-13 input; see

P121...P123

17 Sleep Mode Active

See P240...P242

18 PID Feedback < Min. Alarm

Energizes when PID feedback signal

< P214

19 Inverse PID Feedback < Min.

Alarm

De-energizes when PID feedback

signal < P214

20 PID Feedback > Max Alarm

Energizes when PID feedback

signal > P215

21 Inverse PID Feedback > Max

Alarm

De-energizes when PID feedback

signal > P215

22 PID Feedback within

Min/Max Alarm range

Energizes when PID feedback signal

is within the Min/Max Alarm range;

see P214, P215

23 PID Feedback outside

Min/Max Alarm range

Energizes when PID feedback signal

is outside the Min/Max Alarm range;

see P214, P215

24 Reserved
25 Network Activated

Requires optional communication

module (refer to the network module

documentation).

26 Loss of 0-10V Input
27 Sequencer Controlled

State set in individual sequencer

segments

28 Sequencer Active
29 Sequencer Suspended
30 Sequence Done

End Sequence

31 Actual Speed = 0.0Hz

P142

TB-14 Output

0

0...23 (same as P140)
24 Dynamic Braking

For use with Dynamic Braking option

25...31 (same as P140)