Table 15. show system environment command – Allied Telesis AT-DC2552XS User Manual
Page 123

AT-DC2552SX Switch Command Line Interface User’s Guide
123
The fields are described in Table 15.
Example
This example displays information about the switch, PSUs, and fan
modules:
awplus# show system environment
Table 15. SHOW SYSTEM ENVIRONMENT Command
Field
Description
Overall Status
Indicates the status of the unit. The status is either
“Normal” or “***Fault***.”
Resource ID
Indicates the ID of the module.
Name
Indicates the name of the module. The module
names are:
AT-DC2552XS- Indicates the switch.
AT-PWR06 - Indicates the power supply unit.
FAN Tray 01 or 02 - Indicates a fan module.
ID
Indicates the ID of the sensor.
Sensor (Units)
Indicates the name of the sensor.
Reading
Shows the value that the sensor detected.
Low Limit
Displays the specified maximum temperature.
When no value is set, “-” is displayed.
High Limit
Displays the specified minimum temperature. When
no value is set, “-” is displayed.
Status
Indicates the status of the sensor. The options are:
Ok
fault