Table 24. show log command – Allied Telesis AT-DC2552XS User Manual

Page 171

Advertising
background image

AT-DC2552SX Switch Command Line Interface User’s Guide

Section I: Switch Management

171

Examples

This example displays the event messages in the buffered log from oldest
to newest:

awplus# show log

This example displays 15 newest event messages in the buffered log:

awplus# show log tail 15

This example displays the event messages in the buffered log from newest
to oldest:

awplus# show log reverse

Table 24. SHOW LOG Command

Field

Description

Date

Indicates the date the message was entered in
the buffered log.

Time

Indicates the time the message was entered in
the buffered log.

Facility

This field always displays “user.”

Severity

Indicates the severity of the message. The
severity levels are:

Information: Useful information that can be
ignored during normal operation.

Error: Switch operation is severely
impaired.

Warning: The issue reported by the
message may require manager attention.

Debug: Messages intended for technical
support and software development.

Program[<pid>]

Indicates the program that generated the event
message.

Message

Displays the event message.

Advertising