Syntax

snmp-server location

text

Parameter

text

Specifies the value of the MIB object sysLocation. The maximum
length is 255 alphanumeric characters. Special characters are
permitted with the exception of exclamation marks (!) and question
marks (?).

Mode

Global Configuration mode

Description

Use this command to set the value of the MIB object sysLocation. This
value indicates the physical location of the system.

Confirmation Command

“SHOW SYSTEM” on page 119

Example

This example sets the value of the MIB object sysLocation to “San Jose
2F”:

awplus> enable
awplus# configure terminal
awplus(config)# snmp-server location San Jose 2F