C14030 | epl device type, C14034 | epl identity object, C14035 | epl device type cn – Lenze E94AYCEP User Manual

Page 105: 11 parameter reference

Advertising
background image

Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17

106

11

Parameter reference

11.3

Parameters of the communication module for slot MXI2

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C14030

C14034

C14035

Parameter | Name:

C14030 | EPL device type

Data type: UNSIGNED_32

Index: 10545 = 0x2931

EPL index: 0x1000

The code indicates the device type of the EPL node.
Value is bit-coded:

Bit 1 Bit1
Bit 2 Bit2
Bit 3 Bit3
Bit 4 Bit4

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14034 | EPL identity object

Data type: UNSIGNED_32

Index: 10541 = 0x292D

EPL index: See subcodes

The code indicates the Manufacturer's EPL ID no. for Lenze.
Subcodes

Lenze setting

Info

EPL index

C14034/1

59

(0x3B)

Manufacturer's EPL ID no.

0x1018.0x01

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14035 | EPL device type CN

Data type: UNSIGNED_32

Index: 10540 = 0x292C

EPL index: See subcodes

The code contains the device type ID of the declared Controlled Nodes. Each subcode corresponds to a Controlled

Node with the node ID = subcode number.

When being in the configured status, the values must be identical with the device types stored locally in each node

under

C14030

.

Subcodes

Lenze setting

Info

EPL index

C14035/1

0

EPL device type CN

0x1F84.0x01

...

...

...

...

C14035/100

0

EPL device type CN

0x1F84.0x64

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT