Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17

20

4

Technical data

4.3

Protective insulation

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

The following illustration ...

• shows the arrangement of the terminal strips and the separate potential areas of the Servo

Drive 9400.

• serves to determine the decisive protective insulation between two terminals located in

differently insulated separate potential areas.

[4-1]

Protective insulation in accordance with EN61800-5-1

E94YCXX007

Reinforced insulation

Basic insulation

Functional insulation

Ext. DC

I/O

X4

X6

X6

X5

X7

X7

X8

X8

X3

X2

X1

X105

X105

X106

X100

X107

MXI1

MXI2

Bus

Ext. DC

MSI

MMI

Terminal strip Connection

Terminal strip Connection

X100 L1, L2, L3 (Single Drive only)

X1 CAN on board 9400

+UG, -UG

X2 State bus

X105 U, V, W

24 V (ext.)

Rb1, Rb2 (Single Drive only)

X3 Analog inputs/outputs

X106 Motor PTC

X4 Digital outputs

X107 Control of the motor holding

brake

X5 Digital inputs
X6 Diagnostics
X7 Resolver
X8 Encoder

MXI1, MXI2 Extension module

MMI Memory module

MSI Safety module