C13229 | epl multi-stage node declaration mn, C13231 | epl rpdo, C13232 | epl rpdo – Lenze E94AYCEP User Manual

Page 91: C13233 | epl rpdo, C13231, Codes, 11 parameter reference

Advertising
background image

Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17

92

11

Parameter reference

11.2

Parameters of the communication module for slot MXI1

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13229

C13231

C13232

C13233

Parameter | Name:

C13229 | EPL multi-stage node declaration MN

Data type: UNSIGNED_8

Index: 11346 = 0x2C52

EPL index: See subcodes

This code indicates in which multiplexed cycle the node is queried. The value entered must not exceed the value in

code

C13074

.

If, for instance, the value "3" is entered in code

C13074

, the multiplexed cycle is repeated every three cycles. If now

the value "3" is entered for one node in C13229/x, it is always queried only in the second cycle of the three

multiplexed cycles.
Setting range

(min. value | unit | max. value)

0

Cycles

255

Subcodes

Lenze setting

Info

EPL index

C13229/1

0 cycles

Managing Node

0x1F9B.0xF0

C13229/2

0 cycles

Diagnostics device

0x1F9B.0xFD

C13229/3

0 cycles

router

0x1F9B.0xFE

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13231 | EPL RPDO

Data type: UNSIGNED_64

Index: 11344 = 0x2C50

EPL index: See subcodes

EPL RPDO-1
Subcodes

Lenze setting

Info

EPL index

C13231/1

0

EPL RPDO

0x1600.0x01

...

...

...

...

C13231/32

0

EPL RPDO

0x1600.0x20

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13232 | EPL RPDO

Data type: UNSIGNED_64

Index: 11343 = 0x2C4F

EPL index: See subcodes

EPL RPDO-2
Subcodes

Lenze setting

Info

EPL index

C13232/1

0

EPL RPDO

0x1601.0x01

...

...

...

...

C13232/32

0

EPL RPDO

0x1601.0x20

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13233 | EPL RPDO

Data type: UNSIGNED_64

Index: 11342 = 0x2C4E

EPL index: See subcodes

EPL RPDO-3
Subcodes

Lenze setting

Info

EPL index

C13233/1

0

EPL RPDO

0x1602.0x01

...

...

...

...

C13233/32

0

EPL RPDO

0x1602.0x20

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT