Diagnostics

9.1

LED status displays

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.1.2

Fieldbus status displays

The BS LED indicates the fieldbus status.

E94YCEP001E

BS: Bus Status

LED

Colour

Status

Description

BS

Green

Off

The communication module is not active on the fieldbus or is in the

INIT state.

Blinking

The

POWERLINK

network is in the initialisation phase.

NMT_MS_PREOPERATIONAL_1 / NMT_CS_PREOPERATIONAL_1

Blinking

The

POWERLINK

network is in the initialisation phase with cyclic

traffic.

NMT_MS_PREOPERATIONAL_2 / NMT_CS_PREOPERATIONAL_2

Blinking

The

POWERLINK

node is waiting for the start signal.

NMT_MS_READY_TO_OPERATE / NMT_CS_READY_TO_OPERATE

Blinking

The

POWERLINK

node has not found a Managing Node and is in

Basic Ethernet Mode ( 29)

.

NMT_CS_BASIC_ETHERNET

Blinking

The

POWERLINK

node is in the "Stopped" status (waiting for

disconnection).

NMT_CS_STOPPED

On

The

POWERLINK

node is in the operating phase.

NMT_MS_OPERATIONAL / NMT_CS_OPERATIONAL

1 s

1 s

1 s

50 ms

200 ms

200 ms