C13132 | epl cn: link interruptions, C13136 | epl telegram counter, C13203 | epl cn response error – Lenze E94AYCEP User Manual

Page 88: C13205 | epl cn response error: monit. thresholds, C13132, 11 parameter reference

Advertising
background image

11

Parameter reference

11.2

Parameters of the communication module for slot MXI1

89

Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13132

C13136

C13203

C13205

Parameter | Name:

C13132 | EPL CN: Link interruptions

Data type: UNSIGNED_32

Index: 11443 = 0x2CB3

EPL index: 0x1C10

The code indicates the counter of the Controlled Node for POWERLINK connection interruptions (

C13118

).

Each event is counted. Every single event is followed by an error message. No threshold value management is

implemented.
Display area

(min. value | unit | max. value)

0

4294967295

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13136 | EPL telegram counter

Data type: UNSIGNED_32

Index: 11439 = 0x2CAF

EPL index: 0x1101.0x01

The subcodes of the code indicate a counter for EPL cycles. The counter is started with each mains power-up of the

EPL node at 0. An overflow occurs at 4.294.967.295.
Display area

(min. value | unit | max. value)

0

4294967295

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13203 | EPL CN response error

Data type: UNSIGNED_32

Index: 11372 = 0x2C6C

EPL index: See subcodes

The subcodes of the code indicate Controlled Node-specific cumulative counters for missing PRes frames. The

behaviour corresponds to a node The behaviour corresponds to subcode 1 of the single error counters.

Each subcode corresponds to an EPL node with node ID = subcode number.
Display area

(min. value | unit | max. value)

0

4294967295

Subcodes

Info

EPL index

C13203/1

Managing Node

0x1C07.0xF0

C13203/2

Diagnostics device

0x1C07.0xFD

C13203/3

router

0x1C07.0xFE

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13205 | EPL CN response error: Monit. thresholds

Data type: UNSIGNED_32

Index: 11370 = 0x2C6A

EPL index: See subcodes

Setting range

(min. value | unit | max. value)

0

1000

Subcodes

Lenze setting

Info

EPL index

C13205/1

0

Managing Node

0x1C09.0xF0

C13205/2

0

Diagnostics device

0x1C09.0xFD

C13205/3

9

router

0x1C09.0xFE

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT