C14920 | epl dip switch, 11 parameter reference – Lenze E94AYCEP User Manual

Page 129

Advertising
background image

Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17

130

11

Parameter reference

11.3

Parameters of the communication module for slot MXI2

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C14920

Parameter | Name:

C14920 | EPL DIP switch

Data type: UNSIGNED_8

Index: 9655 = 0x25B7

EPL index: not available

The code outputs the current DIP switch setting of the communication module.

• The switch with the labelling "128" is displayed on the most significant bit, the switch "1" on the least significant

bit.

• The numerical value of C14920 corresponds to the node ID of the communication module.

Node address setting ( 36)

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Advertising