Parameter reference

11.3

Parameters of the communication module for slot MXI2

113

Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C14079

C14095

Parameter | Name:

C14079 | EPL multi-stage node declaration CN

Data type: UNSIGNED_8

Index: 10496 = 0x2900

EPL index: See subcodes

This code indicates in which multiplexed cycle the Controlled Node is queried. The value entered must not exceed

the value in code

C14074

.

If, for instance, the value "3" is entered in code

C14074

, the multiplexed cycle is repeated every three cycles. If now

the value "3" is entered for one node in C14079/x, it is always queried only in the second cycle of the three

multiplexed cycles.
Setting range

(min. value | unit | max. value)

0

Cycles

255

Subcodes

Lenze setting

Info

EPL index

C14079/1

0 cycles

0x1F9B.0x01

...

...

...

C14079/100

0 cycles

0x1F9B.0x64

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14095 | EPL communication status

Data type: UNSIGNED_8

Index: 10480 = 0x28F0

EPL index: 0x1F8C

The code indicates the current NMT status of the EPL node.
Selection list

(read only)

Info

0 Off

NMT_GS_OFF

25 Initialising

NMT_GS_INITIALISING

41 ResetAppl

NMT_GS_RESET_APPLICATION

57 ResetComm

NMT_GS_RESET_COMMUNICATION

121 ResetConfig

NMT_GS_RESET_CONFIGURATION

28 NotActive

NMT_CS_NOT_ACTIVE

NMT_MS_NOT_ACTIVE

29 PreOp1

NMT_CS_PRE_OPERATIONAL_1

NMT_MS_PRE_OPERATIONAL_1

93 PreOp2

NMT_CS_PRE_OPERATIONAL_2

NMT_MS_PRE_OPERATIONAL_2

109 ReadyToOp

NMT_CS_READY_TO_OPERATE

NMT_MS_READY_TO_OPERATE

253 Operational

NMT_CS_OPERATIONAL

NMT_MS_OPERATIONAL

77 Stopped

NMT_CS_STOPPED (only Controlled Node)

30 BasicEthernet

NMT_CS_BASIC_ETHERNET (only Controlled Node)

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT