4 basic ethernet mode, Basic ethernet mode, 5installation – Lenze E94AYCEP User Manual
Page 28
![background image](/manuals/565771/28/background.png)
5
Installation
5.2
Electrical installation
29
Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.2.4
Basic Ethernet Mode
The communication module can be operated in the "Basic Ethernet Mode" for a basic parameter
setting provided that the following applies:
1. Operation of the module with network address 239.
• IP address: 192.168.100.[Node ID]
• see
2. Operation with real time POWERLINK must not be carried out.
3. No integration of a Managing Node (node ID 240) into the standard Ethernet network.
Note!
Operation in the "Basic Ethernet Mode" does not permit any real-time communication.