4 technical data, 1 general data and operating conditions, Technical data – Lenze E94AYCEP User Manual

Page 15: General data and operating conditions, 4technical data

Advertising
background image

Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17

16

4

Technical data

4.1

General data and operating conditions

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4

Technical data

4.1

General data and operating conditions

Range

Values

Order designation

E94AYCEP

Communication profile

POWERLINK V2

Communication medium

S/FTP (Screened Foiled Twisted Pair, ISO/IEC 11801 or EN 50173), CAT 5e

Interface for communication

RJ45, Standard Ethernet (according to IEEE 802.3), 100Base-TX (Fast

Ethernet)

Network topology

Tree, star, line

Max. cable length

Number of nodes x 100 m

Cable length between

2 nodes/hubs

max. 100 m

Baud rate

100 Mbps

Type of node

• Managing Node (support of up to 50 nodes)

• Controlled Node

Adjustable by node address (node ID).

Node addresses

(Node IDs)

240 E94AYCEP is Managing Node (max. 50 nodes)

1 ... 100 E94AYCEP is Controlled Node with another E94AYCEP as

Managing Node.

1 ... 239 E94AYCEP is Controlled Node with Managing Node of another

manufacturer.

Voltage supply

External supply via separate power supply unit

+: U = 24 V DC (20.4 V ... 28.8 V), I = 140 mA

- : Reference potential for external voltage supply

Conformities, approvals

• CE

• UL

(see also hardware manual)

Servo Drives 9400 hardware manual
Here you can find the ambient conditions and data on the electromagnetic compatibility

(EMC), which also apply to the communication module.