C13126 | epl cn: frame collisions, C13127 | epl cn: sync loss, C13131 | epl cn: frame error (crc) – Lenze E94AYCEP User Manual

Page 87: C13131/3, C13127/3, C13127, C13126, C13127/1, C13131/1, 11 parameter reference

Advertising
background image

Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17

88

11

Parameter reference

11.2

Parameters of the communication module for slot MXI1

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13126

C13127

C13131

Parameter | Name:

C13126 | EPL CN: Frame collisions

Data type: UNSIGNED_32

Index: 11449 = 0x2CB9

EPL index: See subcodes

The code indicates the number of POWERLINK collisions detected by the Controlled Node (

C13116

).

Each event is counted. Every single event is followed by an error message. No threshold value management is

implemented.
Setting range

(min. value | unit | max. value)

0

4294967295

Subcodes

Lenze setting

Info

EPL index

C13126/1

0

CumulativeCnt_U32

0x1C0A.0x01

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13127 | EPL CN: Sync loss

Data type: UNSIGNED_32

Index: 11448 = 0x2CB8

EPL index: See subcodes

The Controlled Node expects SoC frames in time intervals which correspond to the cycle time (

C13060

).

The code indicates the error counters for missing SoC frames.

The monitoring response is determined via

C13891/3

.

Setting range

(min. value | unit | max. value)

0

4294967295

Subcodes

Lenze setting

Info

EPL index

C13127/1

0

CumulativeCnt_U32

0x1C0B.0x01

C13127/2

0

ThresholdCnt_U32

0x1C0B.0x02

C13127/3

9

Threshold_U32

0x1C0B.0x03

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13131 | EPL CN: Frame error (CRC)

Data type: UNSIGNED_32

Index: 11444 = 0x2CB4

EPL index: See subcodes

The code indicates the number of frame checksum errors detected by the Controlled Nodes (

C13115

).

The monitoring response is determined via

C13891/4

.

Setting range

(min. value | unit | max. value)

0

4294967295

Subcodes

Lenze setting

Info

EPL index

C13131/1

0

CumulativeCnt_U32

0x1C0F.0x01

C13131/2

0

ThresholdCnt_U32

0x1C0F.0x02

C13131/3

9

Threshold_U32

0x1C0F.0x03

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Advertising