C14229

C14231

C14232

C14233

Parameter | Name:

C14229 | EPL multi-stage node declaration MN

Data type: UNSIGNED_8

Index: 10346 = 0x286A

EPL index: See subcodes

This code indicates in which multiplexed cycle the node is queried. The value entered must not exceed the value in

code

C14074

.

If, for instance, the value "3" is entered in code

C14074

, the multiplexed cycle is repeated every three cycles. If now

the value "3" is entered for one node in C14229/x, it is always queried only in the second cycle of the three

multiplexed cycles.
Setting range

(min. value | unit | max. value)

0

Cycles

255

Subcodes

Lenze setting

Info

EPL index

C14229/1

0 cycles

Managing Node

0x1F9B.0xF0

C14229/2

0 cycles

Diagnostics device

0x1F9B.0xFD

C14229/3

0 cycles

router

0x1F9B.0xFE

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14231 | EPL RPDO

Data type: UNSIGNED_64

Index: 10344 = 0x2868

EPL index: See subcodes

EPL RPDO-1
Subcodes

Lenze setting

Info

EPL index

C14231/1

0

EPL RPDO

0x1600.0x01

...

...

...

...

C14231/32

0

EPL RPDO

0x1600.0x20

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14232 | EPL RPDO

Data type: UNSIGNED_64

Index: 10343 = 0x2867

EPL index: See subcodes

EPL RPDO-2
Subcodes

Lenze setting

Info

EPL index

C14232/1

0

EPL RPDO

0x1601.0x01

...

...

...

...

C14232/32

0

EPL RPDO

0x1601.0x20

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14233 | EPL RPDO

Data type: UNSIGNED_64

Index: 10342 = 0x2866

EPL index: See subcodes

EPL RPDO-3
Subcodes

Lenze setting

Info

EPL index

C14233/1

0

EPL RPDO

0x1602.0x01

...

...

...

...

C14233/32

0

EPL RPDO

0x1602.0x20

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT