C14126

C14127

C14131

Parameter | Name:

C14126 | EPL CN: Frame collisions

Data type: UNSIGNED_32

Index: 10449 = 0x28D1

EPL index: See subcodes

The code indicates the number of POWERLINK collisions detected by the Controlled Node (

C14116

).

Each event is counted. Every single event is followed by an error message. No threshold value management is

implemented.
Setting range

(min. value | unit | max. value)

0

4294967295

Subcodes

Lenze setting

Info

EPL index

C14126/1

0

CumulativeCnt_U32

0x1C0A.0x01

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14127 | EPL CN: Sync loss

Data type: UNSIGNED_32

Index: 10448 = 0x28D0

EPL index: See subcodes

The Controlled Node expects SoC frames in time intervals which correspond to the cycle time (

C14060

).

The code indicates the error counters for missing SoC frames.

The monitoring response is determined via

C14891/3

.

Setting range

(min. value | unit | max. value)

0

4294967295

Subcodes

Lenze setting

Info

EPL index

C14127/1

0

CumulativeCnt_U32

0x1C0B.0x01

C14127/2

0

ThresholdCnt_U32

0x1C0B.0x02

C14127/3

9

Threshold_U32

0x1C0B.0x03

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14131 | EPL CN: Frame error (CRC)

Data type: UNSIGNED_32

Index: 10444 = 0x28CC

EPL index: See subcodes

The code indicates the number of frame checksum errors detected by the Controlled Nodes (

C14115

).

The monitoring response is determined via

C14891/4

.

Setting range

(min. value | unit | max. value)

0

4294967295

Subcodes

Lenze setting

Info

EPL index

C14131/1

0

CumulativeCnt_U32

0x1C0F.0x01

C14131/2

0

ThresholdCnt_U32

0x1C0F.0x02

C14131/3

9

Threshold_U32

0x1C0F.0x03

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT