4 can2_io (node number: 32), Can2_io (node number: 32), Pter 7.4 – Lenze DDS System bus CAN for PLC User Manual

Page 102: System bus (can) for lenze plc devices, Can system blocks, A sync telegram is not required

Advertising
background image

7.4

CAN2_IO (node number: 32)

System bus (CAN) for Lenze PLC devices

CAN system blocks

7−14

L

PLC−Systembus EN 2.0

7.4

CAN2_IO (node number: 32)

This SB serves to transmit event−controlled or time−controlled process data via the system bus.

·

The setting of the transmission mode (event− or time−controlled) is effected via C0356.

(

^ 3−6)

·

A sync telegram is not required.

CAN2_nInW1_a

CAN2_nInW2_a

CAN2_bInB

_b

0...15

CAN2_bInB

_b

16...31

System bus interface

Byte

7

8

5

6

3

4

1

2

Byte

7

8

5

6

3

4

1

2

CAN2_nOutW1_a

CAN2_nOutW2_a

CAN2_nOutW3_a

CAN2_bFDO

_b

16...31

CAN2_dnOutD1_p

CAN2_IO

DINT

WORD

WORD

WORD

16 x BOOL

DINT

Output user data

(8 bytes)

Input user data
(8 bytes)

L

H

L

H

CAN2_bFDO

_b

0...15

16 x BOOL

CAN2_nOutW4_a

WORD

WORD

WORD

16 x BOOL

16 x BOOL

CAN2_nInW3_a

CAN2_nInW4_a

WORD

WORD

CAN2_dnInD1_p

C0868/4

C0868/5

C0869/2

C0868/6

C0868/7

C0866/4

C0866/5

C0863/3

C0863/4

C0867/2

C0866/6

C0866/7

Fig. 7−4

CAN2_IOsystem block

Tip!

Via C0357/2 you can set the monitoring time for the data reception. (Lenze setting: 3000 ms)

·

Further information on this subject can be found in chapter 3.12.1.

(