Response in the case of system bus fault messages, System bus (can) for lenze plc devices, Configuration (can−aux interface) – Lenze DDS System bus CAN for PLC User Manual
Page 84
Advertising
System bus (CAN) for Lenze PLC devices
Configuration (CAN−AUX interface)
6−10
l
PLC−Systembus EN 2.0
6.10.3
Response in the case of system bus fault messages
Overview of the system bus error sources registered by the PLC as well as of the possible settings
for the corresponding response:
Fault message
Possible settings/response
Display
Error
No.
Meaning
TRIP
Message Warning
Fault/QS
P
Off
Code
CE11
122
Communication error CANaux1_IN
(Time monitoring can be set via C2457/1)
ь
−
ь
−
•
C2481
CE12
123
CANaux2_IN communication error
(Time monitoring can be set via C2457/2)
ь
−
ь
−
•
C2482
CE13
124
CANaux3_IN communication error
(Time monitoring can be set via C2457/3)
ь
−
ь
−
•
C2483
CE14
125
BUS−OFF state
(too many faulty telegrams were received)
ь
−
ь
−
•
C2484
• Lenze setting
ü Possible
− Not possible
Advertising