System bus (can) for lenze plc devices, Lenzecandsxdrv.lib function library – Lenze DDS System bus CAN for PLC User Manual

Page 166

Advertising
background image

11.8

L_CanDSxCloseHeartBeat − deactivating the "Heartbeat"

System bus (CAN) for Lenze PLC devices

LenzeCanDSxDrv.lib function library

11−10

L

PLC−Systembus EN 2.0

11.8

L_CanDSxCloseHeartBeat − deactivating the "Heartbeat"

Function

By means of this function, the "Heartbeat" monitoring mechanism of the CanDSx driver is
deactivated again.

·

For the deactivation the transfer parameter bClose has to be set to TRUE.

Declaration

BOOL

L_CanDSxCloseHeartBeat(bClose);

Transfer parameters

Data type

Information/possible settings

bClose

Bool

Deactivating the "Heartbeat" monitoring mechanism.

TRUE The "Heartbeat" monitoring mechanism of the CanDSx driver in the operating

system is deactivated.

Return value

Data type

Value/meaning

Bool

Status

TRUE The "Heartbeat" monitoring mechanism of the CanDSx driver has been

deactivated.

FALSE The "Heartbeat" monitoring mechanism of the CanDSx driver has not been

deactivated.

·

Remedy: function call via transfer parameter bClose = TRUE.

Example

Calling the function in ST:

bReturnCloseHeartBeat :=

L_CanDSxCloseHeartBeat(bClose:=TRUE);