7 can_synchronization (node number: 102), Can_synchronization (node number: 102), System bus (can) for lenze plc devices – Lenze DDS System bus CAN for PLC User Manual

Page 111: Can system blocks, Operating mode

Advertising
background image

System bus (CAN) for Lenze PLC devices

CAN system blocks

7.7

CAN_Synchronization (node number: 102)

7−23

L

PLC−Systembus EN 2.0

7.7

CAN_Synchronization (node number: 102)

This SB can be used to synchronise the internal time base of the controller to the instant of reception
of the sync telegram or of a terminal signal. Thus, the start of cyclic and time−controlled internal
processes (e. g. data transfer from tasks to the DCTRL function block) is effected in a synchronous
manner for all controllers involved in the synchronisation.

CAN_bSyncForInterpolator_b

CAN_Synchronization

CAN_bResetSyncForInterpolartor_b

CAN_nSyncDeviation

CAN_bSyncInsideWindow_b

2

1

Sync telegram

Sync

Control

C1121

C1123

C1122

C0369

C0366

C0363

C1120

C0367
C0368

Sync signal

0

Off

Fig. 7−7

CAN_Synchronizationsystem block

Variable

Data type

Signal type

Address

Display

code

Display

format

Notes

CAN_bSyncInsideWindow_b

Bool

Binary

%IX102.0.0

TRUE:
Sync telegram/signal within the
time slot (C1123)
FALSE:

·

Exit synchronicity

·

No sync telegram/signal

·

Time slot (C1123) too small

CAN_bSyncForInterpolator_b

%IX102.0.1

TRUE:
Sync telegram/signal recognised

CAN_nSyncDeviation

Integer

%IX102.1

Current sync deviation

CAN_bResetSyncForInterpolator
_b

Bool

Binary

%QX102.0.0

TRUE:
Reset CAN_bSyncForInterpolator_b

Operating mode

Code

LCD

Possible settings

IMPORTANT

Lenze

Selection

[C1120] Sync mode

0

CAN sync. source

0

Off

Synchronisation deactivated.

1

Synchronisation via system bus (CAN)

Synchronisation by sync telegram
via system bus.

2

Synchronisation via terminal

Synchronisation by sync signal via
terminal:

·

9300 Servo PLC: X5/E5

·

Drive PLC: X3/I1

·

ECSxA: X6/DI1

Axis synchronisation via system bus (CAN)

The system bus transmits both the sync telegram and the process signals.

Example for applications:

·

Specification of cyclic, synchronised position setpoint information for multi−axis applications
via the system bus.

Advertising