3 node address (node id), Node address (node id), System bus (can) for lenze plc devices – Lenze DDS System bus CAN for PLC User Manual

Page 63: Configuration (fif interface)

Advertising
background image

System bus (CAN) for Lenze PLC devices

Configuration (FIF interface)

5−3

l

PLC−Systembus EN 2.0

5.3

Node address (node ID)

Assign a node address − also called Node ID − within the range of 1 to 63 to each node within the
system bus network as a definite identification.

·

The same node address may not be assigned more than once within the network.

·

The configuration of the node address for the FIF interface of the PLC is effected via code
C2450:

Code

LCD

Possible settings

Information

Lenze

Selection

C2450 CAN1 address

1

1

{1}

63 System bus node address

·

Save modifications with C0003
= 1.

·

Modifications are only valid
after reset node!

Allocation of the node address for the data exchange among Lenze devices

If Lenze devices are provided with node addresses in a consistent ascending order, the identifiers
of the event−controlled data objects (FIF_CAN2_IO/FIF_CAN3_IO) are set in way by the factory which
enables a communication from one device to the other:

L

Node-ID 1

FIF-CAN2_OUT

FIF-CAN2_IN

FIF-CAN3_OUT

FIF-CAN3_IN

L

Node-ID 2

FIF-CAN2_OUT

FIF-CAN2_IN

FIF-CAN3_OUT

FIF-CAN3_IN

L

Node-ID 3

Fig. 5−1

Data exchange among Lenze devices