2 display of the identifiers set, Display of the identifiers set, System bus (can) for lenze plc devices – Lenze DDS System bus CAN for PLC User Manual

Page 79: Configuration (can−aux interface)

Advertising
background image

System bus (CAN) for Lenze PLC devices

Configuration (CAN−AUX interface)

6−5

l

PLC−Systembus EN 2.0

·

Please note that the identifier of the telegram to be transmitted has to comply with the
identifier of the process data input object to be activated.

·

In the case of an individual address allocation, the identifier for the process data objects is
composed as follows:

Identifier + 384 ) value of C2454/x

x = subcode

·

Thus, for the process data objects identifiers in the range of 385 ... 896 can be allocated.

6.4.2

Display of the identifiers set

Via C2455 you can have the identifier displayed which is set for the process data objects.

·

C2455 is a display code, settings cannot be carried out via C2455.

Code

LCD

Possible settings

Information

Lenze

Selection

C2455

1
2
3
4
5
6

CAN Id

CAN1_IN Id
CAN1_OUT Id
CAN2_IN Id
CAN2_OUT Id
CAN3_IN Id
CAN3_OUT Id

g

385

{1}

896 System bus identifier

for the process data objects
CANaux1_IN
CANaux1_OUT
CANaux2_IN
CANaux2_OUT
CANaux3_IN
CANaux3_OUT