System bus (CAN) for Lenze PLC devices

Configuration (FIF interface)

5−7

l

PLC−Systembus EN 2.0

5.7

Synchronisation

Tip!

By means of the CAN_Synchronization SB, the internal time base of the PLC can be synchronised
with the arrival of the sync telegram.

Thus the internal calculating processes (e. g. control oriented processes) of the PLC can be
synchronised with the calculating processes of other nodes which can also process the sync
telegram.

Detailed information on the CAN_Synchronization SB can be found in chapter 7.7.

(

^ 7−23)

5.7.1

FIF−CAN sync response

The response to the reception of a sync telegram can be configured via C2466:

Code

LCD

Possible settings

IMPORTANT

Lenze

Selection

C2466 Sync response

1

FIF−CAN sync response

0

No response

No response

1

Response to sync

PLC responds to a sync telegram
by sending the FIF−CAN1_OUT
object.

5.7.2

FIF−CAN sync identifier

The transmission or reception identifiers of the sync telegram can be configured via C2467/C2468:

Code

LCD

Possible settings

IMPORTANT

Lenze

Selection

C2467 Sync Rx Id

128

1

{1}

256 FIF−CAN sync Rx identifier

Receive identifier for the sync
telegram

C2468 Sync Tx Id

128

1

{1}

256 FIF−CAN sync Tx identifier

Send identifier for the sync
telegram

5.7.3

FIF−CAN sync Tx transmission cycle

The cycle time within which a sync telegram with the identifier set in C2468 is transmitted can be
configured via C2469:

Code

LCD

Possible settings

IMPORTANT

Lenze

Selection

C2469 Sync Tx time

0

0

{1 ms}

65000

0 = Off

FIF−CAN sync time
Sync transmission telegram cycle

Advertising