2 fif_can2_io (node number: 35), Fif_can2_io (node number: 35), Pter 8.2 – Lenze DDS System bus CAN for PLC User Manual

Page 121: System bus (can) for lenze plc devices, Fif−can system blocks, A sync telegram is not required

Advertising
background image

System bus (CAN) for Lenze PLC devices

FIF−CAN system blocks

8.2

FIF_CAN2_IO (node number: 35)

8−1

L

PLC−Systembus EN 2.0

8.2

FIF_CAN2_IO (node number: 35)

This SB serves to the transmission of event− or time−controlled process data via the function interface
of the Drive PLC.

·

The setting of the transmission mode (event− or time−controlled) is effected via C2456.

(

^ 5−6)

·

A sync telegram is not required.

FIF_CAN2_nInW1_a

FIF_CAN2_nInW2_a

FIF_CAN2_bInB

_b

0...15

FIF_CAN2_bInB

_b

16...31

FIF System bus interface

Byte

7

8

5

6

3

4

1

2

Byte

7

8

5

6

3

4

1

2

FIF_CAN2_nOutW1_a

FIF_CAN2_nOutW2_a

FIF_CAN2_nOutW3_a

FIF_CAN2_bFDO

_b

16...31

FIF_CAN2_dnOutD1_p

FIF_CAN2_IO

DINT

WORD

WORD

WORD

16 x BOOL

DINT

Output user data

(8 bytes)

Input user data
(8 bytes)

L

H

L

H

FIF_CAN2_bFDO

_b

0...15

16 x BOOL

FIF_CAN2_nOutW4_a

WORD

WORD

WORD

16 x BOOL

16 x BOOL

FIF_CAN2_nInW3_a

FIF_CAN2_nInW4_a

WORD

WORD

FIF_CAN2_dnInD1_p

C2493/4

C2493/5

C2493/6

C2493/7

C2492/4

C2492/5

C2491/3

C2491/4

C2492/6

C2492/7

Fig. 8−2

FIF_CAN2_IO system block

Tip!

Via code C2457/2 you can set the monitoring time for the data reception. (Lenze setting: 3000 ms)

·

Further information on this subject can be found in chapter 5.10.1.

(

^ 5−9)