Rockwell Automation Publication 1791ES-UM001D-EN-P - May 2013

29

Understand the Operation of Safety Functions

Chapter 2

Safety Precautions

Legislation and Standards

Read this section to familiarize yourself with related legislation and standards
information. Relevant international standards include the following:

IEC 61508 (SIL 1-3)
IEC 61131-2
IEC 60204-1
IEC 61000-6-2
IEC 61000-6-4

The modules received the following certification from ODVA, when product is
marked.

Table 3 - Controlling Device Requirements

Device

Requirement

Allen-Bradley Bulletin Safety Components

Emergency stop switches

Use approved devices with direct opening mechanisms complying with IEC/EN
60947-5-1.

Bulletin 800F, 800T

Door interlocking switches,
limit switches

Use approved devices with direct opening mechanisms complying with IEC/EN
60947-5-1 and capable of switching microloads of 24V DC 5 mA.

Bulletin 440K, 440G, 440H for interlock switch
Bulletin 440P, 802T for limit switch

Safety sensors

Use approved devices complying with the relevant product standards,
regulations, and rules in the country where used.

Any Guardmaster product

Relays with forcibly- guided
contacts,
contactors

Use approved devices with forcibly-guided contacts complying with EN 50205. For
feedback purposes, use devices with contacts capable of switching micro loads of
24V DC 5 mA.

Bulletin 700S, 100S

Other devices

Evaluate whether devices used are appropriate to satisfy the requirements of
safety category levels.

ATTENTION: As serious injury can occur due to loss of required safety function,
follow these safety precautions:

Do not use test outputs of the modules as safety outputs.
Do not use EtherNet/IP standard I/O data or explicit message data as

safety data.

Do not use LED indicators on the I/O modules for safety operations.
Do not connect loads beyond the rated value to the safety outputs.
Wire the Guard I/O modules properly so that 24V DC line does not touch

the safety outputs accidentally or unintentionally.

Clear previous configuration data before connecting devices to the

network.

Set suitable IP addresses before connecting devices to the network.
Perform testing to confirm that all of the device configuration data and

operation is correct before starting system operation.

When replacing a device, configure the replacement device suitably and

confirm that it operates correctly.

When installing or replacing modules, clear any previous configuration

before connecting input or output power to the device.