Alarm In 1
Alarm In 2

Off

Alarm input not configured.

Solid green

Alarm input configured; no alarm detected

Blinking red

Major alarm detected.

Solid red

Minor alarm detected.

Setup

Off

The switch is configured as a managed switch.

Solid green

The switch is in initial setup.

Blinking green

The switch is in initial setup, fault recovery, or initial setup is incomplete.

Solid red

The switch failed to start initial setup or recovery because there is no available switch port to connect to the

management station. Disconnect a device from a switch port, then press the Express Setup button on the switch.

Ports—Each combo port has two status indicators: one for the SFP module and one for the RJ45 connector. The appropriate status indicator is active for the active port.

Off

No link present on the port.

Solid green

Port link; no activity.

Flashing green and off

Link is active and healthy.

Alternating green and amber

There is a fault or error on the link.

Solid amber

The port is disabled.

EIP Net—The EIP Net status indicator shows the network status of the switch.

Off

Power to the switch is off or is not properly connected.

Solid green

The switch has an established CIP connection to one or more attached devices.

Blinking green

The switch has an IP address but the switch does not have an established connection to one or more attached devices.

Blinking red

One or more connections to attached devices have timed out.

Solid Red

The switch has detected that its IP address is already in use by another device in the network.

Blinking green and red

The switch is running its power-on self-test (POST).

Status —In this mode, the port status indicators show the status of the ports. This is the default mode.

Off

No link.

Solid green

No activity on link.

Flashing green

Link activity.

Solid brown

Port has been disabled.

Yellow

An error has disabled the port.

Flashing green and amber

Faulty link.

Flashing amber

Smartports configuration mismatch on port.

Solid amber

Port is faulty, disabled due to an error, or is in an STP-blocked state.

Smartports—In this mode, each port image shows the applied port role. For information about Smartports, see

Optimize Ports through Smartports Port Roles on page 83

.